61-0251-66 [Discontinued]Opticap Gamma Compatible Sterilizing Grade XLT30 Durapore 0.1μm 5/8In HB/HB 1/Pk 1ST KVVLG3THH1
Analyzer, Testing Equipment

61-0251-66 [Discontinued]Opticap Gamma Compatible Sterilizing Grade XLT30 Durapore 0.1μm 5/8In HB/HB 1/Pk 1ST KVVLG3THH1

model: 61-0251-66
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-66Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-66
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm gamma compatible 5/8in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    63.3mL/min at 390kPa (56psig) wetted with water
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

2-1769-01 Fraction Collector 7410002JA
Analyzer, Testing Equipment

2-1769-01 Fraction Collector 7410002JA

model: 2-1769-01 brand: Bio-Rad Laboratories, Inc.
63-6531-06 [Discontinued]BD Difco (TM) Acetate Availability Test Agar Medium 274210
Analyzer, Testing Equipment
62-8349-30 Opticap Sterile XLT20 Express SHC 0.5+0.2μm 1.5inTC/TC 1/Pk KHGES2TTT1
Analyzer, Testing Equipment
62-8468-09 [Discontinued]Anti-phospho-Axin-1 (Thr485) Antibody ABN1032
Analyzer, Testing Equipment