61-0251-17 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 0.5/0.2/0.22μm 3/4In TC/TC 1/Pk 1ST KVSSA10FF1
Analyzer, Testing Equipment

61-0251-17 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 0.5/0.2/0.22μm 3/4In TC/TC 1/Pk 1ST KVSSA10FF1

model: 61-0251-17
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-17Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-17
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.56
  • Filter bore diameter, μm: 0.5 / 0.2 / 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester; hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 multimedia 0.5/0.2/0.22μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    10.8mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Highest operating temperature, ℃: 80 °C
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0310-99 Lanthanum(III) Oxide 112220 500G 1.12220.0500
Analyzer, Testing Equipment

61-0310-99 Lanthanum(III) Oxide 112220 500G 1.12220.0500

model: 61-0310-99 brand: Merck Millipore Corporation
62-8411-90 InSolution(TM) Cdk1 Inhibitor IV, RO-3306 217721-2MG
Analyzer, Testing Equipment
61-6430-04 [Discontinued]COL-CAP FRITS 4mm; 0.5μm N9303716
Analyzer, Testing Equipment
61-0331-61 Trans-Cinnamaldehyde for Synthesis 802505 5mL 8.02505.0005
Analyzer, Testing Equipment

61-0331-61 Trans-Cinnamaldehyde for Synthesis 802505 5mL 8.02505.0005

model: 61-0331-61 brand: Merck Millipore Corporation