61-0250-44 [Discontinued]Opticap XLT30 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA3TBB1
Analyzer, Testing Equipment

61-0250-44 [Discontinued]Opticap XLT30 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA3TBB1

model: 61-0250-44
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-44Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-44
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.22μm 1in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    40mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0267-04 PEL2 PLC 5k V 2m2 1EA P2C005V20
Analyzer, Testing Equipment

61-0267-04 PEL2 PLC 5k V 2m2 1EA P2C005V20

model: 61-0267-04 brand: Merck Millipore Corporation
61-6435-08 [Discontinued]Elite-Wax Etr,15m,0.53mmid,2.00μm N9316568
Analyzer, Testing Equipment
61-0304-28 Thymolphthalein Indicator Acs,Reag. pH Eur 108175 5G 1.08175.0005
Analyzer, Testing Equipment
61-9065-37 [Discontinued]With Teflon Plug Standard Fluorescence Cell F11-SQ-1 6210-27101
Analyzer, Testing Equipment