61-0250-26 [Discontinued]Opticap Sterilizing Grade XL10 Durapore Phobic 0.22μm 3/4In TC/TC 1/Pk 1ST KVGBA10FF1
Analyzer, Testing Equipment

61-0250-26 [Discontinued]Opticap Sterilizing Grade XL10 Durapore Phobic 0.22μm 3/4In TC/TC 1/Pk 1ST KVGBA10FF1

model: 61-0250-26
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-26Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-26
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port with double O-ring seal
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 Durapore hydrophobicity 0.22μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    124kPa (18psig) 60//40% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 126℃ for 30 minutes for 20 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Nitrogen diffusion flow rate, 23 °C: ? 10mL/min at 170kPa (25psig) 60//40% IPA/water
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8482-20 [Discontinued]QCM(TM) Gelatin Invadopodia Assay (Red), Fluorescent; 32 assays (1 kit) ECM671
Analyzer, Testing Equipment
3-6355-01 [Discontinued]Video Eyepiece Camera MIC-132
Analyzer, Testing Equipment
61-9638-84 Syringe Filter PVDF030022
Analyzer, Testing Equipment

61-9638-84 Syringe Filter PVDF030022

model: 61-9638-84 brand: Membrane Solutions
62-8412-76 β-catenin/Tcf inhibitor III, iCRT3 219332-10MG
Analyzer, Testing Equipment