61-6927-58 Visible Spectrum Achromat Focal Length 40.2mm ATL-30-40PY2
Product Description
Product Model: 61-6927-58Product Brand: SIGMAKOKI CO., […]
Contact Us
Product Details
Product Model: 61-6927-58
Product Brand: SIGMAKOKI CO., LTD.
Features
- This is an air-gap type acromatic condensing lens with no adhesive attached to the lens.
- It is ***d as a condensing lens for a 532 nm high-power laser machine with a built-in coaxial epi-illumination observation system.
- Chromatic aberration is corrected in a wide wavelength range centered around 532 nm by optimization based on lens design.
- For lenses with a focal length of 60 mm or more, laser collimation can be narrowed down to a spot diameter that is almost diffraction limited.
- Since the lens is coated with an anti-reflection film, the loss of light due to reflection is small, and the beam can be concentrated efficiently.
- A separately sold protective glass can be installed to protect the lens from flying light ca***d by laser processing.
- A special lens holder (LHF-M34-30) is available for fixing the condenser lens.
- * Use the condenser lens when you want to focus an object at infinity, or when you want to *** the point light source as parallel light.
- Sufficient optical performance cannot be obtained when the camera is ***d for close-range imaging.
- * The condenser lens has an orientation that allows light to enter.
- * Be sure to allow parallel light to enter from the upper side (look at the engraving on the side of the lens barrel upright).
- * Doing so can ca*** chromatic aberration and spherical aberration to become large, which can increase the size of the focus spot, and can ca*** blurred images.
- If you *** the instrument outside the specified wavelength range, chromatic aberration may increase and transmittance may be reduced.
- * When using with a high-power laser or near a light source that emits heat, the condenser lens may become hot and the focal length of the condenser lens may change.
- * Heat dissipation measures are necessary when irradiating for a long time.
- * If you want to reduce the condensing spot diameter, widen the incident beam diameter (1/e^2) to about half the effective diameter of the condensing lens.
Spec
-
[
common specification]
- Material: Crown series glass - (air gap) - flint series glass
- Frame material: Aluminum surface treatment: Black anodic oxide
- Design wavelength: 486nm, 532nm, 656nm
- Coating: Visible zone reflective prevention film
- Incident allowable angle: ±1°
- Laser durability: 1J/cm2 (pulse width 10ns, Repeat frequency 20Hz)
- [Individual specification]
- Focus distance f: 40.2mm
- Length L: 22mm
- NA : 0.34
- WD: 30.1mm
- RoHS conform product
Related product recommendations
You may also be interested in the following products
61-0192-09 Millisnap System Large Black Adapter for Incubation On Solid Media Cassette, 1/Pk 1ST MSSM10001
model: 61-0192-09
brand: Merck Millipore Corporation
61-6882-27 Color Temperature Conversion Filter 0.467 LA-50S-20
model: 61-6882-27
brand: SIGMAKOKI CO., LTD.
62-8522-41 [Discontinued]Anti-NFATc1, clone 7A6 MABS409
model: 62-8522-41
brand: Sigma Aldrich Japan(Millipore)
61-0310-13 M Color Test(TM) Phosphoric Acid Test Measurement Principle: Colorimetric Analysis (Using Tower-Type Colorimetric Unit), PMB Method 1.0-2.5-5.0-7.5-10mg/L P2O5 1.3-3.3-6.7-10.0-13.4mg/L PO4(3-) Mcolortest(TM) 111138 200Tests 1.11138.0001
model: 61-0310-13
brand: Merck Millipore Corporation