61-0247-80 Opticap XL2 Durapore 0.45μm W/O Pref 1.5In. TC/TC 3/Pk 3 x 1ST KPHLA02TT3
Analyzer, Testing Equipment

61-0247-80 Opticap XL2 Durapore 0.45μm W/O Pref 1.5In. TC/TC 3/Pk 3 x 1ST KPHLA02TT3

model: 61-0247-80
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-80Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-80
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 900
  • Filtration area, m

    2

    : 0.09
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 2 (5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: SN1M065A4
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL2 Durapore 0.45μm without pre-filter 1-1/2in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0227-26 Aervent CTGR Cart Filt 10In. 0.2μm Code 7 1/Pk 1ST CTGR71TP1
Analyzer, Testing Equipment
62-8387-35 [Discontinued]Anti-acetylated-Src (Lys7); 100 μg 07-1322
Analyzer, Testing Equipment

62-8387-35 [Discontinued]Anti-acetylated-Src (Lys7); 100 μg 07-1322

model: 62-8387-35 brand: Sigma Aldrich Japan(Millipore)
62-8385-08 Anti-dimethyl-Histone H3 (Lys9); 100 μg 07-441
Analyzer, Testing Equipment

62-8385-08 Anti-dimethyl-Histone H3 (Lys9); 100 μg 07-441

model: 62-8385-08 brand: Sigma Aldrich Japan(Millipore)
62-8446-57 Anti-GABA B Receptor R1; 50 μL AB2256
Analyzer, Testing Equipment

62-8446-57 Anti-GABA B Receptor R1; 50 μL AB2256

model: 62-8446-57 brand: Sigma Aldrich Japan(Millipore)