61-0247-77 Opticap XL2 Durapore 0.45μm W/O Pref 3/4In. TC/HB 3/Pk 3 x 1ST KPHLA02FH3
Analyzer, Testing Equipment

61-0247-77 Opticap XL2 Durapore 0.45μm W/O Pref 3/4In. TC/HB 3/Pk 3 x 1ST KPHLA02FH3

model: 61-0247-77
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-77Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-77
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 900
  • Filtration area, m

    2

    : 0.09
  • Filter bore diameter, μm: 0.45
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 2 (5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL2 Durapore 0.45μm without pre-filter TC/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Bubble point, 23 °C:


    193kPa (28 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Positive direction - 345 (50) at 25℃ (without pre-filter); reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0325-08 [Discontinued]Cyanoacetic Acid for Synthesis 800252 250G 8.00252.0250
Analyzer, Testing Equipment
62-8516-85 Anti-DRD4, clone 2B9; 100 μg MABN125
Analyzer, Testing Equipment

62-8516-85 Anti-DRD4, clone 2B9; 100 μg MABN125

model: 62-8516-85 brand: Sigma Aldrich Japan(Millipore)
1-1970-01 Suction Filter Holder with Receiver Flask 16510
Analyzer, Testing Equipment
61-0359-44 P-Anisidine Chloride for Synthesis 820103 50G 8.20103.0050
Analyzer, Testing Equipment

61-0359-44 P-Anisidine Chloride for Synthesis 820103 50G 8.20103.0050

model: 61-0359-44 brand: Merck Millipore Corporation