61-0247-56 Opticap XL5 Polygard-CN 5.0μm 3/4In. TC/TC 1/Pk 1ST KN50A05FF1
Analyzer, Testing Equipment

61-0247-56 Opticap XL5 Polygard-CN 5.0μm 3/4In. TC/TC 1/Pk 1ST KN50A05FF1

model: 61-0247-56
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0247-56Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0247-56
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.18
  • Diameter, cm (inch): 10.7 (4.2)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Polypropylene
  • Housing: Polypropylene
  • Format: Single Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL5 Polygard-CN 5.0μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 5.0
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 483 (70) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8413-49 CFTR Inhibitor II, GlyH-101 219671-5MG
Analyzer, Testing Equipment

62-8413-49 CFTR Inhibitor II, GlyH-101 219671-5MG

model: 62-8413-49 brand: CBC(Merck)
2-6513-01 [Discontinued]HPLC Column 93072
Analyzer, Testing Equipment
62-8454-25 [Discontinued]Anti-FXR-B; 100 μL AB10305
Analyzer, Testing Equipment

62-8454-25 [Discontinued]Anti-FXR-B; 100 μL AB10305

model: 62-8454-25 brand: Sigma Aldrich Japan(Millipore)
62-8370-13 Vasoactive Intestinal Peptide, Human, Porcine, and Rat 05-23-2101-0.5MG
Analyzer, Testing Equipment