61-0243-30 Opticap XLT20 Polysep II 1.0/0.2μm 1.5In. TC/TC 1/Pk 1ST KGW3A2TTT1
Analyzer, Testing Equipment

61-0243-30 Opticap XLT20 Polysep II 1.0/0.2μm 1.5In. TC/TC 1/Pk 1ST KGW3A2TTT1

model: 61-0243-30
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0243-30Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0243-30
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.92
  • Length, cm (inch): 20
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Double Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT20 Polysep II 1.0/0.2μm 1-1/2in. TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Nominal bore diameter, μm: 1.0 / 0.2
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 290


    mg per capsule after a 10


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 10L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0357-54 3-Chloro-4-Fluoroaniline for Synthesis 818752 25G 8.18752.0025
Analyzer, Testing Equipment
61-0304-28 Thymolphthalein Indicator Acs,Reag. pH Eur 108175 5G 1.08175.0005
Analyzer, Testing Equipment
61-0311-17 Samarium(III) Oxide 99 112321 10G 1.12321.0010
Analyzer, Testing Equipment

61-0311-17 Samarium(III) Oxide 99 112321 10G 1.12321.0010

model: 61-0311-17 brand: Merck Millipore Corporation
62-8466-46 Anti-Oxytocin receptor (OXTR) ABN297
Analyzer, Testing Equipment

62-8466-46 Anti-Oxytocin receptor (OXTR) ABN297

model: 62-8466-46 brand: Sigma Aldrich Japan(Millipore)