toner
61-9416-76 Gas Detector Tube Acetic Acid with Calibration Certificate (With Certificate Of Test) 81L
Product Description
Product Model: 61-9416-76Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9416-76
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
- The concentration of various gases in the air can be easily measured by direct reading.
- You can measure by changing the detector tube with a single detector (pump).
- Beca*** it is directly readable, there is no individual difference and it is accurate.
- Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.
Spec
- Detecting tube name: 81L acetic acid
- Number of measurements of 1 box: 10
- Expiration date (year): 2 (refrigeration required)
- Measurement gas name: Acrylic Acid (stabilized with MEHQ)
- Measurement range: 0.45 - 18ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Isovaleric Acid
- Measurement range: 0.38 - 15ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Formic acid
- Measurement range: 0.5 - 20ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Propionic Acid
- Measurement range: 0.25 - 10ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Methacrylic Acid (stabilized with MEHQ)
- Measurement range: 0.35 - 14ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Valeric Acid
- Measurement range: 0.38 - 15ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Acetic acid
- Measurement range: 0.125 - 25.0ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: -
- Measurement gas name: Acetic anhydride
- Measurement range: 0.15 - 6ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Butyric Acid
- Measurement range: 0.325 - 13ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
Related product recommendations
You may also be interested in the following products
1-6940-11 [Discontinued]Portable Conductivity Meter (CON450) ECCONWP45003K
model: 1-6940-11
brand: AS ONE Corporation
62-8593-87 PTFE Binder Filter TF -98 φ 20 080130-098020
model: 62-8593-87
brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.
65-3500-62 Sealed Coupled Meter D Type Heat-Resistant Vibration-Resistant Pressure Range (MPA): -0.1~0.1 315-D880X0.1-0.1MPA-HV
model: 65-3500-62
brand: Asahi Gauge Manufacturing
2-1340-01-20 Bimetal Thermometer 50 with Calibration Certificate BM-T-90S
model: 2-1340-01-20
brand: AS ONE Corporation